PMMA Light Covers
Acrylic light covers with high transmission and long-term colour stability – for decorative, architectural and general lighting where the cover is seen.
What we supply
Where the cover is part of the design rather than just protection, acrylic is usually the right material. It transmits more light, it holds a cleaner surface, and it does not yellow the way standard polycarbonate can over time.
We extrude PMMA covers in flat, curved, half-round and custom sections, with opal or frosted diffusion where the light source should not be visible, and clear where it should.
| Material | PMMA (acrylic), UV-stable grades |
|---|---|
| Key property | High light transmission and UV stability |
| Typical fittings | Decorative, architectural, commercial and residential luminaires |
| Form | Flat covers, half-rounds, tubes, custom sections |
| Surface | Clear, opal, frosted, matte, prismatic |
| Transmittance | Set to your optical target |
| Colour | Clear, opal, tinted or matched to RAL / Pantone |
| Length | Cut to length to your specification |
What we work to
| Material | PMMA (acrylic), UV-stable optical grades |
|---|---|
| Section width | up to 400 mm across the profile |
| Critical die dimensions | ±0.1 mm on the dimensions that carry the fit |
| Wall thickness | quoted against your drawing |
| Transmittance | 0-97%, tuned to the fixture rather than to a default |
| Surface | clear, matte, frosted, embossed or prismatic |
| Colour | 100+ shades matched to RAL or Pantone |
| Minimum order | from 500 pcs per profile |
| Sample to mass production | around 6 weeks, tooling included |
Acrylic is chosen for how it carries light and for how long it keeps carrying it. The trade is impact – where a cover can be struck, say so on the drawing and the conversation moves to PC or to co-extrusion.
How to specify a PMMA light cover
A light cover is doing two jobs that do not agree. It has to pass as much light as the photometric calculation assumes, and it has to hide what is behind it. Push transmission up and the LEDs become visible; push diffusion up and the fixture gets dim. The whole specification is that trade, and it cannot be resolved by picking a material off a list.
PMMA is usually the right side of that trade. It transmits more in the visible range than polycarbonate, it is among the most UV-stable optical plastics available, and it replicates fine prism geometry cleanly. That is why prismatic diffusers and linear lenses are normally quoted in acrylic rather than PC.
What it does not do is take a knock. Acrylic is the more brittle of the two, and it loses impact strength as temperature drops – a cover that survived summer handling can crack in a winter container. Where the fixture is low-mounted, in a corridor, on transport, or anywhere a ladder or a trolley can reach it, the usual answer is either PC or a co-extrusion with a PC structural layer behind an acrylic optical face.
On the drawing, the single most useful number is the transmittance target at the wall thickness you are actually running. “Opal” spans a wide range and turns first-off approval into an argument. Give us a number, a surface description and a colour reference and the sample comes back close enough to approve in one pass.
What to put on the drawing
- Section at 1:1 with wall thickness dimensioned separately
- Transmittance target as a number at that wall thickness
- Diffusion requirement: how well the LED source has to be hidden
- Impact and cleaning regime the cover has to survive
- Surface: clear, matte, frosted, embossed or prismatic
- Cut length, packing and annual volume
Where a PMMA light cover goes wrong
Four failures account for most of the acrylic covers that come back, and all four are decided before the first metre is pulled.
Stress cracking at the snap
An undercut that is too aggressive for acrylic forces the wall further than it wants to go, and the crack appears weeks later. Check the undercut against wall thickness before the die is cut.
Yellowing that is not UV
Not every yellow part is a UV failure. Running the melt too hot degrades the resin on the way out and the colour is already in the profile at take-off.
Brittle failure in cold transit
Acrylic loses impact strength as it gets colder. Packing has to be specified for the shipping route, not for the factory floor.
Transmission measured on the wrong thickness
Transmission is thickness-dependent. A number measured on a 3 mm sample is not the number you get at 1.5 mm, and the difference is visible in the photometric result.
None of these show up on a datasheet. They show up in first-off inspection and in the field, which is why we keep a retained sample from each batch rather than relying on a certificate alone.
Options we build into the profile
- Opal and frosted diffusion at a defined transmittance
- Tinted acrylic for decorative luminaires
- Prismatic surface for glare-controlled decorative fittings
- Curved and half-round sections
- Protective film to keep surfaces clean through assembly
- Cutting, drilling and machining to your drawing
Related Products
Custom Lighting Profiles
Sections developed from your drawing.
View →Custom LED Profiles
Profiles for LED linear luminaires.
View →LED Diffuser Profiles
Diffusers tuned for LED pitch hiding.
View →Custom LED Lenses
Linear lens profiles for beam control.
View →PC Lighting Profiles
Polycarbonate profiles for tough applications.
View →PMMA Lighting Profiles
Acrylic profiles for clarity and UV stability.
View →Frequently Asked Questions
Send us your drawing or sample
Or email your drawing to info@leddiffuserfactory.com · WhatsApp +37259205909 · WeChat +8615867897761