PC Light Covers

Polycarbonate light covers extruded for fittings that have to survive impact – industrial luminaires, tri-proof fixtures and public-area lighting.

What we supply

A polycarbonate cover is the part that takes the hit. In warehouses, car parks, factories, schools and transport buildings the cover is struck, kicked or dropped, and acrylic will crack where polycarbonate will not.

We extrude PC covers to your section – clear, opal or prismatic – with wall thickness set for the impact requirement, and cut and pack them to drop straight into your assembly line.

PC light cover - capability
MaterialPolycarbonate (PC), UV-stabilised and FR grades available
Key propertyVery high impact resistance
Typical fittingsIndustrial luminaires, tri-proof fixtures, bulkheads, vandal-resistant fittings
FormFlat covers, half-rounds, tubes and custom sections
SurfaceClear, opal, frosted, prismatic
Wall thicknessSet to the impact requirement of the fitting
LengthCut to length to your specification
CertificationProduced under an ISO 9001:2015 quality system

What we work to

Polycarbonate light cover - capability envelope
Section widthup to 400 mm across the cover
Critical die dimensions±0.1 mm on the fit that locates the cover in the housing
Wall thicknessfrom 1.0 mm where UL 94 V-0 is required on the PC grades we run
Flame ratingUL 94 V-0 from 1.0 mm and V-2 down to 0.40 mm, per the UL component plastics cards
Impactpolycarbonate is specified where the cover may be struck in handling or in service
Surfaceclear, matte, frosted, embossed or prismatic
Colourclear, opal, or 100+ shades matched to RAL or Pantone
Lengthcut to your specification
Minimum orderfrom 500 pcs per profile
Sample to mass productionaround 6 weeks, tooling included

The flame rating and the wall thickness are the same decision. V-0 on our PC grades starts at 1.0 mm, so a section drawn at 0.8 mm cannot carry it however the compound is tuned. That is worth settling before the die, because changing wall thickness afterwards means a new die.

How to specify a PC light cover

Polycarbonate covers are chosen for one of three reasons, and it helps to know which one applies before the section is drawn. The first is impact: a cover that gets struck in handling, in installation or in service, where acrylic would crack. The second is flame performance, where the fixture has to pass a rating and the cover is part of the assembly. The third is heat, where the cover sits close enough to the LED that a material with more thermal headroom is the safer choice.

Each reason pushes the design in a different direction. Impact wants wall thickness and a section without sharp internal corners, because that is where a crack starts. Flame performance wants enough wall to carry the rating and a grade that is actually listed on the UL card, not merely one that is “flame retardant” in a supplier brochure. Heat wants a section that can move without stress whitening as it warms and cools, which usually means generous radii rather than a tight fit.

The cost of PC is optical rather than mechanical. It transmits slightly less than acrylic in the visible range – a few points, depending on grade and wall – and it is more prone to yellowing under UV unless the grade is stabilised. Where both matter, co-extrusion puts a UV-stable or high-transmission layer on the outside and keeps the structural performance of PC underneath. That is a common answer for exterior covers and for fixtures that are cleaned with aggressive chemicals.

For the drawing, the fit matters more than the outside profile. Give us the snap or slide geometry that locates the cover, the gap to the housing, and the wall thickness separately from the outside dimensions. If the cover has to meet a flame rating, tell us the rating and the thinnest wall in the section, because those two together decide whether the grade you want can be used at all.

What to put on the drawing

  • Section at 1:1 with wall thickness dimensioned separately
  • The fit: snap undercut, slide rail, tongue depth, cover-to-housing gap
  • Flame rating required, and the thinnest wall in the section
  • Transmittance target if the cover is also the diffuser
  • Service temperature and cleaning chemicals, if the fixture is exterior or washdown
  • Cut length, protective film and packing method

Where a PC cover goes wrong

Polycarbonate forgives impact and punishes design detail. These four are the recurring ones.

A rating that the wall cannot carry

V-0 starts at 1.0 mm on the grades we run. A section drawn thinner than that cannot be brought into compliance by changing compound, so the wall thickness has to be settled with the rating, not after the first-off.

Stress whitening at the snap

PC is tough but it does not like being forced. An undercut that requires the wall to flex beyond its strain limit shows as a white mark at the snap, and later as a crack. Radii and undercut depth are checked against wall thickness before tooling.

Yellowing on exterior covers

Standard PC drifts towards amber under UV. Where the cover faces daylight, the grade has to be UV-stabilised, or the optical face co-extruded with a stabilised layer. This is a material choice, not a process fix.

Dimensional drift after annealing

PC sections move slightly as internal stress relaxes. If a cover is dimensioned tight to the housing and then annealed or stored warm, the fit can change. Tolerances on the locating features have to allow for it.

Underneath all four is the same rule: on polycarbonate, the wall thickness and the radii are the design, and everything else follows. We review those two before quoting, because they are the only ones that cannot be fixed downstream.

Options we build into the profile

  • Thick-wall sections for high-impact and vandal-resistant fittings
  • UV-stabilised PC for semi-exterior and exterior use
  • Flame-retardant grades where the specification requires it
  • Prismatic or frosted inner surface for glare control
  • Clear or opal to your transmission target
  • Cutting, drilling and end preparation to your drawing

Frequently Asked Questions

Polycarbonate is dramatically tougher than acrylic and is the standard choice for vandal-resistant and industrial fittings. The wall thickness is set to the impact class your fitting needs.
Yes with UV-stabilised grades. Standard PC weathers less well than PMMA, so we specify a stabilised grade for exterior installations.
Yes. Send a sample cover or a dimensioned drawing and we reproduce the section for replacement or for your own production.
On the polycarbonate grades we extrude, V-0 starts at 1.0 mm and V-2 holds down to 0.40 mm, per the UL component plastics cards. Those are material ratings rather than a certificate on the finished profile, so the rating has to be read against the thinnest wall in your section.
It depends which failure you can tolerate. PC wins on impact and holds a flame rating; PMMA wins on transmission and resists UV yellowing without additives. For exterior covers that also take knocks, the usual answer is a co-extruded profile with a stabilised optical face on a PC carrier.
A few points in the visible range, depending on grade and wall thickness – not a large difference, but enough to notice next to an acrylic part. If your fixture is already at its lumen target, that margin matters; if it has headroom, PC buys you impact resistance for very little optical cost.
We can extrude the flame-retardant PC grades and hold the wall thickness the rating needs. What we do not do is claim a finished-part certification we do not hold – the rating is a material property, and the assembly certification stays with the luminaire maker.

Send us your drawing or sample

Our engineers review geometry, material and tooling feasibility and come back with a profile proposal and quotation.

Or email your drawing to info@leddiffuserfactory.com · WhatsApp +37259205909 · WeChat +8615867897761

Scroll to Top