Office Lighting Profiles

Low-glare diffusers and lens sections for office luminaires – profiles designed around UGR targets and long hours at a desk.

What this application demands from the profile

Office lighting is judged on glare. People sit under the fitting for eight hours, and a luminaire that is technically efficient but uncomfortable on screen is a failed installation. That makes the profile’s optical surface the critical part.

In practice this means prismatic and micro-prism structures rather than plain diffusion, and a section designed with the luminaire’s UGR target in mind rather than chosen from a catalogue.

Office lighting profiles - what we supply
Luminaire typeOffice, workspace, meeting room and education luminaires
Profile roleLow-glare diffuser, lens plate or housing section
MaterialsPMMA for transmission and prism detail; PC where required
SurfacePrismatic, micro-prism, frosted or opal
GlareSurface structure designed to the UGR target
UniformityDiffusion tuned so the lit surface reads evenly
GeometryWide flat and suspended sections engineered against sag

What we work to

Office lighting profile - capability envelope
MaterialPC or PMMA, single extrusion or co-extruded
Section widthup to 400 mm across the profile
Critical die dimensions±0.1 mm on the dimensions that carry the fit
Wall thicknessquoted against your drawing
Transmittance0-97%
Surfaceclear, matte, frosted, embossed or prismatic
Glare controlprismatic and micro-prismatic faces - selected to a UGR target
Minimum orderfrom 500 pcs per profile
Sample to mass productionaround 6 weeks, tooling included

Office lighting is specified against glare and against the people working under it. Light output is the easy half; the optical surface is the half that decides whether the space gets accepted.

What office lighting asks of a profile

Office lighting is judged by the people sitting under it, and they judge it on glare rather than on lumens. A fitting that puts out the specified output can still fail the space if the optical surface lets the source into the field of view. That makes the diffuser choice a compliance question rather than a cosmetic one.

UGR is the number that gets written into the specification, and it is achieved by the optical surface. Plain diffusion spreads light but does not control the angle at which it leaves; prismatic and micro-prismatic faces do. The trade is output – glare control costs some transmission – and it is a trade worth making explicitly at design stage rather than discovering at handover.

The second office constraint is uniformity along long runs. Open-plan floors are lit with continuous lines, and any variation in transmission, colour or joint detail shows up as a visible change across the ceiling. That is a repeatability requirement, and it is met with retained samples and measured references rather than with a datasheet.

Colour temperature interaction is the last one. Polymer is not neutral – the material and the diffusing agent both shift the apparent colour of the light slightly. If a project has a stated colour temperature, send it, and we will check the combination on a sample before production.

What to put on the drawing

  • UGR or glare target for the space
  • Section at 1:1 with wall thickness dimensioned separately
  • Transmittance target as a number at the running wall thickness
  • Optical surface: prismatic, micro-prismatic or diffuse
  • Run length, joint detail and colour consistency requirement
  • Cut length, packing and annual volume

Where an office profile goes wrong

Four failures account for most office fittings that get complained about, and three of them are discovered by the people working underneath.

Glare missed until handover

A diffuser chosen on output alone can fail a UGR assessment. The surface has to be selected against the glare target.

Visible variation along a long run

Transmission, colour and joint detail all vary slightly. Across an open-plan ceiling, slight becomes visible.

Colour temperature shifted by the material

Polymer and diffusing agent both move the apparent colour of the light. Check the combination on a sample if the project states a colour temperature.

Re-order that does not match

Office refurbishments happen wing by wing. Without a retained sample, the second batch is a fresh mix and the difference is on the ceiling.

Office work is approved by the occupants. Glare target, optical surface and retained samples are the three things that decide whether it gets approved.

Profile requirements

  • Prismatic or micro-prism surfaces for UGR-controlled luminaires
  • Diffusion tuned so the lit face reads uniformly
  • Wide flat sections that stay flat over the fitting length
  • Consistent dimensions for clean assembly
  • Colour consistency across phased office fit-outs
  • Protective film so optical surfaces arrive clean

Frequently Asked Questions

Yes. Send the UGR target and luminaire layout; we design the surface structure and confirm performance on prototype sections before releasing production tooling.
For glare control, generally yes – prismatic structures control beam spread and glare rather than only scattering light. Plain opal diffuses but does little for glare.
Yes. Tell us the programme and we plan colour consistency and delivery across phases.
One selected against the UGR target for the space. Prismatic and micro-prismatic faces control glare in a way plain diffusion does not, at some cost to output.
The optical surface and the section determine the result, and the assembled fitting is what gets assessed. Send the target and the section and we will work to it.
Slightly – material and diffusing agent both have an effect. If the project states a colour temperature, we check the combination on a sample.
From 500 pcs per profile, around six weeks from drawing to production including tooling.

Send us your drawing or sample

Our engineers review geometry, material and tooling feasibility and come back with a profile proposal and quotation.

Or email your drawing to info@leddiffuserfactory.com · WhatsApp +37259205909 · WeChat +8615867897761