Linear Light Profiles
Continuous extruded sections for linear luminaires – runs, coves, suspended systems and architectural lines, cut to the length your fixture needs.
What we supply
Linear lighting is where extrusion shows its advantage: the profile is continuous, the cost per metre is low, and the section can carry the diffuser, the housing and the fixing geometry in one piece. Long runs also expose problems – bow, twist, colour variation between batches and visible joints.
We design the section so it extrudes straight and stays straight, control colour batch to batch, and cut to the length your assembly line needs so joints land where you want them.
| Application | Linear luminaires, coves, suspended and surface systems |
|---|---|
| Materials | PMMA, PC, PC/PMMA co-extrusion |
| Section | Diffuser, housing, U-channel, or combined |
| Length | Cut to length - standard fixture lengths or your specification |
| Straightness | Section designed and calibrated for stable long runs |
| Surface | Clear, matte, frosted, prismatic |
| Joining | Geometry can be designed to disguise joints between lengths |
| Colour control | Matched between batches for continuous runs |
What we work to
| Material | PC or PMMA, single extrusion or co-extruded |
|---|---|
| Section width | up to 400 mm across the profile |
| Critical die dimensions | ±0.1 mm on the dimensions that carry the fit |
| Wall thickness | quoted against your drawing |
| Transmittance | 0-97% |
| Surface | clear, matte, frosted, embossed or prismatic |
| Colour | 100+ shades matched to RAL or Pantone |
| Minimum order | from 500 pcs per profile |
| Sample to mass production | around 6 weeks, tooling included |
A linear profile is judged along its length, not at a cross-section. Straightness, twist and the way light behaves at the joints decide whether a run looks continuous – and none of those appear on a section drawing.
How to specify a linear light profile
Linear lighting is where extrusion earns its keep: the section stays constant and the length is whatever the building needs. It is also where the failure modes are least visible on paper. A run can be dimensionally perfect at every cut end and still look wrong when it is lit, because what the eye reads is continuity – the seam between two lengths, the shadow at a corner, the falloff where one profile ends and the next begins.
The section has to carry three things that are rarely drawn: how the cover clips in and how much it bows between clips, how the LED strip is positioned relative to the optical face, and what happens at the joint. Send those and the rest of the geometry follows. Leave them out and the first-off will fit and the installation will not.
Diffusion is the other half. In a linear fixture the LED pitch and the distance from the strip to the cover decide whether you see a row of dots or a continuous line. Transmission alone does not tell you that – a cover that reads 85% on a sample can still hotspot if it sits too close to the strip. Give us the pitch and the gap and we will size the diffusion to it.
For continuous runs, ask for cut-length tolerance and joint detail on the drawing rather than inheriting them. A gap of half a millimetre per joint accumulates over a corridor, and it is far cheaper to specify than to shim on site.
What to put on the drawing
- Section at 1:1, with clip positions and bow between clips
- LED pitch and the distance from strip to optical face
- Joint detail and cut-length tolerance for continuous runs
- Transmittance target as a number, plus surface finish
- Glare requirement if the space is an office – UGR target
- Cut length, packing and annual volume
Where a linear profile goes wrong
Four failures account for most of the linear runs that get complained about, and all four are visible only once the fixture is lit and installed.
Hotspots along the LED pitch
Transmission is not diffusion. If the strip sits too close to the cover or the pitch is too wide, the run reads as a row of dots no matter how good the material is.
Bow between clips
A thin cover supported at long intervals sags under its own weight, and the sag shows as a shadow line. Clip spacing belongs on the drawing.
Visible joints on a continuous run
Cut-length tolerance and end squareness accumulate. Over a long run, small errors become a visible step at every joint.
Glare missed until handover
A linear fixture aimed at a workstation fails on UGR, not on light output. The optical surface has to be chosen against the glare target, not picked for how it looks on a sample card.
These are installation-visible failures, which is why we ask for the LED pitch, the clip spacing and the joint detail before quoting rather than after first-off.
Options we build into the profile
- Diffuser and housing combined in a single co-extruded section
- Suspension, clip and end-cap geometry extruded into the profile
- Prismatic diffusion for low-glare continuous runs
- Corner and connector solutions for architectural layouts
- Length cutting and packing by run length
- Colour consistency controlled across production batches
Related Products
Custom Lighting Profiles
Sections developed from your drawing.
View →Custom LED Profiles
Profiles for LED linear luminaires.
View →LED Diffuser Profiles
Diffusers tuned for LED pitch hiding.
View →Custom LED Lenses
Linear lens profiles for beam control.
View →PC Lighting Profiles
Polycarbonate profiles for tough applications.
View →PMMA Lighting Profiles
Acrylic profiles for clarity and UV stability.
View →Frequently Asked Questions