Office Lighting Profiles
Low-glare diffusers and lens sections for office luminaires – profiles designed around UGR targets and long hours at a desk.
What this application demands from the profile
Office lighting is judged on glare. People sit under the fitting for eight hours, and a luminaire that is technically efficient but uncomfortable on screen is a failed installation. That makes the profile’s optical surface the critical part.
In practice this means prismatic and micro-prism structures rather than plain diffusion, and a section designed with the luminaire’s UGR target in mind rather than chosen from a catalogue.
| Luminaire type | Office, workspace, meeting room and education luminaires |
|---|---|
| Profile role | Low-glare diffuser, lens plate or housing section |
| Materials | PMMA for transmission and prism detail; PC where required |
| Surface | Prismatic, micro-prism, frosted or opal |
| Glare | Surface structure designed to the UGR target |
| Uniformity | Diffusion tuned so the lit surface reads evenly |
| Geometry | Wide flat and suspended sections engineered against sag |
What we work to
| Material | PC or PMMA, single extrusion or co-extruded |
|---|---|
| Section width | up to 400 mm across the profile |
| Critical die dimensions | ±0.1 mm on the dimensions that carry the fit |
| Wall thickness | quoted against your drawing |
| Transmittance | 0-97% |
| Surface | clear, matte, frosted, embossed or prismatic |
| Glare control | prismatic and micro-prismatic faces - selected to a UGR target |
| Minimum order | from 500 pcs per profile |
| Sample to mass production | around 6 weeks, tooling included |
Office lighting is specified against glare and against the people working under it. Light output is the easy half; the optical surface is the half that decides whether the space gets accepted.
What office lighting asks of a profile
Office lighting is judged by the people sitting under it, and they judge it on glare rather than on lumens. A fitting that puts out the specified output can still fail the space if the optical surface lets the source into the field of view. That makes the diffuser choice a compliance question rather than a cosmetic one.
UGR is the number that gets written into the specification, and it is achieved by the optical surface. Plain diffusion spreads light but does not control the angle at which it leaves; prismatic and micro-prismatic faces do. The trade is output – glare control costs some transmission – and it is a trade worth making explicitly at design stage rather than discovering at handover.
The second office constraint is uniformity along long runs. Open-plan floors are lit with continuous lines, and any variation in transmission, colour or joint detail shows up as a visible change across the ceiling. That is a repeatability requirement, and it is met with retained samples and measured references rather than with a datasheet.
Colour temperature interaction is the last one. Polymer is not neutral – the material and the diffusing agent both shift the apparent colour of the light slightly. If a project has a stated colour temperature, send it, and we will check the combination on a sample before production.
What to put on the drawing
- UGR or glare target for the space
- Section at 1:1 with wall thickness dimensioned separately
- Transmittance target as a number at the running wall thickness
- Optical surface: prismatic, micro-prismatic or diffuse
- Run length, joint detail and colour consistency requirement
- Cut length, packing and annual volume
Where an office profile goes wrong
Four failures account for most office fittings that get complained about, and three of them are discovered by the people working underneath.
Glare missed until handover
A diffuser chosen on output alone can fail a UGR assessment. The surface has to be selected against the glare target.
Visible variation along a long run
Transmission, colour and joint detail all vary slightly. Across an open-plan ceiling, slight becomes visible.
Colour temperature shifted by the material
Polymer and diffusing agent both move the apparent colour of the light. Check the combination on a sample if the project states a colour temperature.
Re-order that does not match
Office refurbishments happen wing by wing. Without a retained sample, the second batch is a fresh mix and the difference is on the ceiling.
Office work is approved by the occupants. Glare target, optical surface and retained samples are the three things that decide whether it gets approved.
Profile requirements
- Prismatic or micro-prism surfaces for UGR-controlled luminaires
- Diffusion tuned so the lit face reads uniformly
- Wide flat sections that stay flat over the fitting length
- Consistent dimensions for clean assembly
- Colour consistency across phased office fit-outs
- Protective film so optical surfaces arrive clean
Frequently Asked Questions
Send us your drawing or sample
Or email your drawing to info@leddiffuserfactory.com · WhatsApp +37259205909 · WeChat +8615867897761